AI data centres (AIDCs) need backup power that is instant, large and steadily lower in carbon. No single product achieves all three; the strongest solution combines five levers: battery-first response, lower-carbon fuels, coordinated generation and storage, on-site solar, and data that proves the results. MPMC, a Shanghai-based manufacturer of battery energy storage systems, generator sets and the EMS and SCADA that link them, supplies every lever from its own factories.

Five Levers for Lower-Carbon Backup

1. Battery-First Response

MPMC’s HBD-A battery energy storage systems integrate with the generator set array to provide UPS-level millisecond response, so short disturbances are covered silently and without emissions. Units from 125 kW / 261 kWh to 1,125 kW / 2,170 kWh use LFP 314Ah cells rated for 8,000 cycles at 90% depth of discharge, with liquid cooling, VSG, black start and grid-forming capability, and on-grid and off-grid switching on every model, with seamless switching available as an option.

2. Lower-Carbon Fuels for the Generator Sets

Selected Cummins models support HVO to EN 15940 and B20 blends, and MPMC’s platform also covers natural gas and biofuel at B35 and above. On MPMC’s 18 MW biodiesel project in Indonesia, B35 lowers lifecycle CO2 by up to 85% compared with petroleum diesel and complies with RED II and RFS standards. Natural gas generator sets reach electrical efficiency of at least 38%, and total energy utilisation of 80% or more where heat is recovered.

3. Generation and Storage Working as One

MPMC’s Twins Power MPME2700S-2-SC twin-engine diesel generator set, rated 2,702 kW / 3,377.5 kVA prime at 13.8 kV, dispatches its two Perkins engines according to load for up to 40% fuel saving at low load, and combines backup, peak shaving and EMS control. Paired with commercial and industrial battery storage, which handles peak shaving and valley filling, load support and smoothing of load fluctuations, it lets generation and storage complement each other. At ten off-grid stations in Dubai, the same principle of battery plus generator set operation cut daily fuel use by 10.56% and OPEX by about 20% per station.

4. On-Site Solar

HBD-A storage captures rooftop or campus PV and supplies it later, while DC-coupled HBD-DC 410 and HBD-DC 5000 models, with up to 5,015 kWh per unit, suit large solar-plus-storage installations. The same battery provides peak shaving and frequency regulation when it is not needed for backup.

5. Data That Proves the Results

MPMC’s self-developed SCADA provides real-time monitoring, automated monthly and annual reports and ten years of data retention under an SL3-level cybersecurity framework, giving operators the records they need for sustainability reporting, with Starlink satellite communication as a backup link.

Table 1. Five levers for low-carbon AIDC backup

Lever

MPMC solution

Carbon benefit

Battery-first response

HBD-A, 125-1,125 kW per unit

Short events covered without fuel

Lower-carbon fuels

HVO and B20 on selected Cummins models; B35+ biofuel

Up to 85% lower lifecycle CO2 with B35

Generation plus storage

Twins Power MPME2700S-2-SC with C&I storage

Up to 40% fuel saving at low load

On-site solar

HBD-A and HBD-DC storage

Renewable energy stored for later use

Measured results

SCADA with automated reports

Ten years of verifiable data

0b178c3873424dd80c22d573606a6a25

MPMC HBD-A Series HBD-1000-2000 containerised battery energy storage system.

How the Levers Combine in Practice

A typical low-carbon AIDC design places HBD-A storage between the grid connection and the critical load for instant response and daily peak shaving, sizes containerised generator sets of 1,000 kVA to 3,000 kVA per unit, or Twins Power units, for extended outages on lower-carbon fuel, and adds solar wherever roof or land space allows. One EMS coordinates the whole system, so the battery covers the events it is sized for and the generator sets start when an outage runs on. Every generator set is load-tested from 0% to 110% in MPMC’s CNAS-accredited test centre, including a room that simulates 40°C or 50°C ambient.

Table 2. MPMC references behind each part of the architecture

Reference

Scale

Relevance

Data centre, UAE

3 MW

MTU-powered sets at 6 kV

Changhang Power Station (data centre), UAE

12 MW

MTU-powered data-centre generation

Data-centre backup, United States

36 MW

Large-scale backup power

8 MWh BESS delivered to Europe

5 × 2,097 kWh

HBD-1000-2000A, dual-PCS architecture

Green power plant, Hungary

8 MWh

Frequency regulation, peak shaving, load balancing

D7c99a52eabad97ce8d8f95b56e75ce3

MTU-powered MPMC generator set built for a data centre in the UAE.

Planning Low-Carbon AIDC Backup With MPMC

• Set the share of events to be covered by storage

• Choose generator set fuel, including HVO or biofuel

• Consider Twins Power units for generation-storage coordination

• Plan solar and reporting requirements